City & Guilds 2330.
1 - List the basic precautions to be taken when about to carry out work in a public area:
Awnser (i) Erect barriers and/or tape off the area.
(ii) Post warning notices in appropriate positions.
(iii) Inform all persons who may be affected of the work to be carried out.
Your Awnser

2 - Design calculations involving conductors and an overcurrent protection device is most likely satisfied when:
d In is not less than the design current Ib.
  Wrong

3 - If the cable is totally enclosed in Thermal Insulation for a distance of 2 m, the correction factor (Ci) will be:
a 0.5.
  Wrong

4 - An arrow appearing through an electronic symbol means the value of the device is:
c fixed.
  Wrong

5 - A 12V battery is connected across a set of resistors in series, values being, 60? 30?, 100? and 45?. The current flowing in the circuit is:
d 51 mA.
  Wrong

6 - Where motor isolators are remote from the motor they must be:
a capable of being locked off.
  Wrong

7 - The purpose of an installation specification is to inform the:
d contractor of the clients requirements.
  Wrong

8 - An RCBO is a device which is used as:
c both an overcurrent and residual current protection device.
  Wrong

9 - The legal requirement for electrical equipment to be maintained in good order is laid down in the:
d Electricity at Work Regulations 1989.
  Wrong

10 - MΩ is the abbreviation used for:
c megohms.
  Wrong

11 - Warning signs with a blue background are:
c Mandatory signs.
  Wrong

12 - A length of copper wire has a resistance of 8 ?. What would be the resistance if the length of wire were halved and the cross sectional area doubled:
a 2 Ω.
  Wrong

13 - Which of the following does not determine the frequency of the Periodic Inspection and Testing of an installation:
a the competence of the tester.
  Wrong

14 - DC motors create a constant, stationary, magnetic field in the conductors attached to the:
b yoke.
  Wrong

15 - The type of fault which occurs when a phase conductor comes in contact with a neutral conductor is called:
b a short circuit fault.
  Wrong

16 - The IEE Regulations are designed to provide:
a safety from fire, shock and burns.
  Wrong

17 - The maximum earth fault loop impedance, permitted by BS 7671, on a TN system for a ring final circuit protected by a 30 A BS 1361 fuse is:
b 1.92 Ω.
  Wrong

18 - The minimum depth through which a sheathed cable can pass through a joist is:
d 50 mm.
  Wrong

19 - A black fire extinguisher contains:
b carbon dioxide.
  Wrong

20 - If two equal wattage lamps were connected in series the volt drop across each of them would:
a be the same.
  Wrong

21 - A STAR connected system has a line voltage of 1000V, what is the phase voltage:
b 577V.
  Wrong

22 - Protection against objects greater than 1mm diameter has an IP classification of:
b IP4X.
  Wrong

23 - A three phase cage rotor induction motor is required to operate on a 50 Hz supply and run at a speed of approximately 730 rpm. The number of pole pairs required will be:
b 4.
  Wrong

24 - Instrument test leads should comply with:
c HSE Guidance Note GS 38.
  Wrong

25 - The insulation resistance of two circuits is of 40M? an 36? respectively. When tested together what is the total insulation resistance:
d 19 MΩ.
  Wrong

26 - Which of the following type of fire extinguisher would you not use on an electrical equipment fire:
c Foam extinguishers.
  Wrong

27 - An overload current is:
d an overcurrent occurring in a circuit which is electrically sound.
  Wrong

28 - If he plates of a parallel plate capacitor are increased in area, the capacitance will:
b increase.
  Wrong

29 - Electrical equipment users should be:
a capable of inspecting equipment for obvious defects.
  Wrong

30 - If a cable run measured on a drawing with a scale of 1:25 is 65 cm, what is the actual length of the cable run:
c 16.25m.
  Wrong

Your Score was out of 30

 

 